industrial 350 bhp electric hot water boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Atmospheric / Natural Gas Fired; High Temperature Indoor Hot Water Boilers; Steam Boilers. hospitals to industrial process manufacturing - these heavy duty watertube steamers are available in sizes from 9.5 to 250 Boiler Horsepower. These near-condensing boilers are built with steel fintubes and designed to last a lifetime. They are 100 Get Price
Boiler - 13 (ME Bd. Oct. 1986) A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 5%, heating surface area is 0.91 m 2/boiler Up, and the heating value of fuel is 18,400 Kcal/kg. The total coal available in the bunker is 50,000 kg.Get Price
Charles Hoskins joined his elder brother George (1847-1926) in Sydney in 1876, operating a small engineering workshop at Hay Street, Ultimo.Around 1889, they moved to larger premises in Wattle Street, Ultimo and established a foundry, pipe-works and boiler shop. This plant was expanded in 1902. It was pipe manufacturing that would lead to their success.Get Price
Dec 28, 2021 · Thermal Solution's Arctic Condensing Ultra High-Efficiency Hot Water Boiler Series are natural gas-fired boilers with efficiencies of up to 95%. Each ARC model comes with a 100° delta-T with low minimum flows and has variable primary or primary/secondary piping.Get Price
A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam generating Get Price
This will also entail energy efficiency improvements like gas-fired make-up air heat and gas-fired domestic hot water. The 2 pipe loop that the boiler supplies is distributed to water-sourced heat pump units mounted to the ceiling on each floor. Fairywood Industrial IIGet Price
Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.Get Price
In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price
Portable Boiler Rooms. A Portable Boiler Room, or PBR, contains all the necessary components to start, run and maintain high capacity steam and hot water service. This includes a packaged boiler with burner, feedwater treatment, storage and …Get Price
Past ME Board Problem A boiler feed pump receives 45 li./s of water at 190C and enthalpy of 839.33 kJ/kg. It operates against a head of 952 m with efficiency of 70%. Estimate the water leaving temperature assuming that the temperature rise is due to the inefficiency of the input energy. a. 190.96 C. c. 199.71 C. b. 194.66 C. d. 200 C. Solution Get Price
Boiler Repair Base Charge: Bldg. Code Sec. 118.4(3) $41.62: 1/1/2021: Building Code - Boilers: Boiler Repair Base Charge plus 2% of Valuation: Bldg. Code Sec. 118.4(3) Calculation: 1/1/2014: Mechanical Code - Boilers: Boiler Operator permit - New: Mech. Code Sec. 123: $80.63: 1/1/2021: Mechanical Code - Boilers: Boiler Operator permit - Renewal Get Price