industrial 200 bhp horizontal hot water boilers
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam generating Get Price
These requirements apply to boilers with rated input of 8,000,000 Btu/h or less that are not packaged boilers and to all packaged boilers. Minimum efficiency requirements for boilers cover all capacities of packaged boilers. Maximum capacity — minimum and maximum ratings as provided for and allowed by the unit's controls.Get Price
A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam generating Get Price
Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.Get Price
These requirements apply to boilers with rated input of 8,000,000 Btu/h or less that are not packaged boilers and to all packaged boilers. Minimum efficiency requirements for boilers cover all capacities of packaged boilers. Maximum capacity — minimum and maximum ratings as provided for and allowed by the unit's controls.Get Price
In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price
Nov 01, 2008 · It has already been extensively used in the construction of existing biofuel industrial plants. A typical biofuel facility comprises reactors, cooling towers, boilers, process pipe, process and utility pumps, storage tanks and heat exchange coils and will use many hundreds of tonnes of stainless steel sheet, plate and pipe.Get Price
Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.Get Price
In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price