combined 150 bhp water tube boiler
Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Past ME Board Problem Determine the water horsepower of a centrifugal water pump which has an input of 3.5 Hp if the pump has an 8 in. nominal size suction and 6 in. nominal size discharge and handles 150 gpm of water of 150F. The suction line gage shows 4 in. Hg vacuum and the discharge gage shows 26 psi.Get Price
Water in Q5–2 Boiler reservoirs at temperature of 400C and – 200C. The heat transfer to the heat engine is 2000KJ and net work output of combined engine refrigerator plant is 360KJ. Given that : Air supplied to magic tube = 2 kg Inlet condition at magic tube = 4 bar, 20°C Exit condition : Two equal mass streams, one at – 20°C Get Price
Past ME Board Problem Determine the water horsepower of a centrifugal water pump which has an input of 3.5 Hp if the pump has an 8 in. nominal size suction and 6 in. nominal size discharge and handles 150 gpm of water of 150F. The suction line gage shows 4 in. Hg vacuum and the discharge gage shows 26 psi.Get Price
In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price
Boiler in a Box. For times when all you need is a boiler. Our Boiler in a Box systems include a package fire-tube boiler with up to 800 HP of power, installed expertly into a standard shipping container. If you have plant feedwater treatment already in place, the Boiler in a Box may be the right package for you.Get Price
Apr 28, 2013 · Boiler. Equipment which is similar to fired heater/furnace having tubes insides to produce steam. Boiler Feed Water. See BFW definition. Brake Horse Power. See BHP definition. Bromine Number. The amount of bromine in grams absorbed by 100 grams of a sample. The number indicates the degree of unsaturation.Get Price
In commercial or industrial boiler installations, boilers are rated based on their square feet of heating surface. Packaged boilers today are commonly rated on the basis that 5 sq. ft. of heating surface will produce 1 boiler horsepower, or 33, 500 btu of useful heat, and some claim even less surface required per BHP.Get Price
Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.Get Price
A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam generating Get Price
Boiler in a Box. For times when all you need is a boiler. Our Boiler in a Box systems include a package fire-tube boiler with up to 800 HP of power, installed expertly into a standard shipping container. If you have plant feedwater treatment already in place, the Boiler in a Box may be the right package for you.Get Price
Dec 19, 2020 · 379. A water tube boiler has a capacity of 1000 kg/hr of steam. The factor of evaporation is 1.3, boiler rating is 200%, boiler efficiency is 65% and heating surface area is 0.91 m 2 per bo.Hp. and the heating value of fuel is 18,400 kCal/kg. The total coal available in the bunker is 50,000 kg.Get Price
A water tube boiler evaporated 5.05 kg of water per second from a feed water temperature of 104.44 °C to steam at 1241.1 kPa and quality of 0.97; weight of coal fuel per second 0.57 kg; higher heating value of coal as fired, 11,800 Btu/lb. Determine the rate of absorption in kJ/s, the boiler horsepower, and the efficiency of steam generating Get Price
Apr 28, 2013 · Boiler. Equipment which is similar to fired heater/furnace having tubes insides to produce steam. Boiler Feed Water. See BFW definition. Brake Horse Power. See BHP definition. Bromine Number. The amount of bromine in grams absorbed by 100 grams of a sample. The number indicates the degree of unsaturation.Get Price